English
English 中文
vertical hot water pump IRG circulating pump vertical hot water centrifugal pump IRG hot water pump
  • vertical hot water pump
  • IRG circulating pump
  • vertical hot water centrifugal pump
  • IRG hot water pump
vertical hot water pump
vertical hot water pump
IRG hot water circulating pump
IRG type vertical hot water pipeline pump series single-stage single-suction pipeline centrifugal pump belongs to high temperature pump series. It adopts the performance parameters of IR type centrifugal pump, and is designed and manufactured according to international standards on the basis of general pipeline pump. This series of products has the advantages of high efficiency and energy saving, low noise, reliable performance, no leakage, convenient installation and use, etc.
Flow Rate: 1.5~1200 m3/h
Head Lift: 8~150 m
Power: 0.18~2500 kW
Product Description
Summarize:


IRG type vertical hot water pipeline pump series single-stage single-suction pipeline centrifugal pump belongs to high temperature pump series. It adopts the performance parameters of IR type centrifugal pump, and is designed and manufactured according to international standards on the basis of general pipeline pump. This series of products has the advantages of high efficiency and energy saving, low noise, reliable performance, no leakage, convenient installation and use, etc.

Type Designation:
Example: IRG 50 160 (I) A(B)
IRG——IRG single stage single suction pipeline centrifugal pump
50 ——Nominal diameter of pump inlet and outlet (mm)
160——Nominal outer diameter of impeller (mm)
(I) - Traffic classification
A(B) - The impeller is cut for the first tim
Generally used in:
IRG type hot water high temperature pipeline pump is widely used in: energy, chemical industry, textile, papermaking, and hotels and restaurants, such as boiler high temperature hot water pressurized circulation transportation and urban heating system circulation pumps, IRG type operating temperature T<120 ℃. The operating temperature of GRG hot water high temperature pump is T<240℃.
Advantage:
1. The hot water pipeline pump is a vertical structure, the inlet and outlet diameters are the same, and are located on the same center line. It can be installed in the pipeline like a valve. The appearance is compact and beautiful, the floor area is small, and the construction investment is low. The protective cover can be placed outdoors.
2. The impeller of the hot water pipeline pump is directly installed on the elongated shaft of the motor. The axial dimension is short and the structure is compact. The pump and motor bearings are reasonably arranged, which can effectively stabilize the radial and axial loads generated by the pump operation, thus ensuring the pump The operation is stable, the vibration is small, and the noise is low.
3. The shaft seal of the high temperature pipeline pump adopts tungsten carbide to graphite, hard alloy and other materials, which effectively prolongs the service life of the mechanical seal.
4. The high-temperature pipeline pump is easy to install and maintain, no need to disassemble the pipeline system, just remove the nut of the pump joint seat to extract all the rotor parts.
5. The pipeline pump can be operated in series or in parallel according to the requirements of use, that is, the needs of flow and head.
6. The pump can be installed in a solid or horizontal manner according to the requirements of the pipeline arrangement.
Working conditions:
1. The maximum working pressure of the IRG hot water pipeline pump system is less than or equal to 1.6Mpa, and the static pressure test pressure of the pump is 2.5Mpa. Please indicate the system working pressure when ordering. When the working pressure of the pump system is greater than 1.6Mpa, it should be put forward separately when ordering, so that the over-current part and the connecting part of the pump are made of cast steel during manufacture.
2. The ambient temperature of the hot water pipeline pump is less than 40℃, and the relative humidity is less than 95%.
3. The volume content of solid particles in the medium conveyed by the hot water pipeline pump does not exceed 0.1% of the unit volume, and the particle size is less than 0.2mm.

Note: If the medium used is with fine particles, please specify it when ordering, so that the manufacturer can use the wear-resistant mechanical seal.
Performance Data:
MODEL CAPACITY HEAD EFFECIENCY POWER
(m 3 /h) (m) (%) (kw)
15-80 1.5 8 34 0.18
20-110 2.5 15 34 0.37
20-160 2.5 32 25 0.75
25-110 4 15 42 0.55
25-125 4 20 36 0.75
25-125A 3.6 16 35 0.55
25-160 4 32 32 1.5
25-160A 3.7 28 31 1.1
32-125 5 20 44 0.75
32-125A 4.5 16 43 0.5
40-100 6.3 12.5 54 0.55
40-100A 5.6 10 52 0.37
40-125 6.3 20 46 1.1
40-125A 5.6 16 45 0.75
40-160 6.3 32 40 2.2
40-160A 5.9 28 39 1.5
40-160B 5.5 24 38 1.1
40-200 6.3 50 33 4
40-200A 5.9 44 31 3
40-200B 5.3 36 29 2.2
40-250 6.3 80 28 7.5
40-250A 5.9 70 28 5.5
40-250B 5.5 60 27 4
40-100(I) 12.5 12.5 62 1.1
40-100(I)A 11 10 60 0.75
40-125(I) 12.5 20 58 1.5
40-125(I)A 11 16 57 1.1
40-160(I) 12.5 32 52 3
40-160(I)A 11.7 28 51 2.2
40-160(I)B 10.4 22 50 1.5
40-200(I) 12.5 50 46 5.5
40-200(I)A 11.7 44 45 4
40-200(I)B 10.6 36 44 3
40-250(I) 12.5 80 38 11
40-250(I)A 11.6 70 38 7.5
40-250(I)B 10.8 60 37 7.5
40-250(I)C 10 52 36 5.5
50-100 12.5 12.5 62 1.1
50-100A 11 10 60 0.75
50-125 12.5 20 58 1.5
50-125A 11 16 57 1.1
50-160 12.5 32 52 3
50-160A 11.7 28 51 2.2
50-160B 10.4 22 50 1.5
50-200 12.5 50 46 5.5
50-200A 11.7 44 45 4
50-200B 10.6 36 44 3
50-250 12.5 80 38 11
50-250A 11.6 70 38 7.5
 · · · · · ·        
Inquiry
Welcome to send your requirement and we will contact you in 24h.
Name:
Country :
*Email:
Phone :
*Message :
Home
Products
Inquiry
WhatsApp