Self-priming centrifugal pumps, which are centrifugal pumps with self-priming capabilities that do not require a water supply to operate, are extensively utilized across several sectors. However, before commencing, the preparation and inspection work is especially crucial to guarantee the safe and effective operation of self-priming pumps. In order to help new and old users to master the operation of self-priming pump operation points, this paper will be introduced in detail under the start of self-priming transfer pumps need to check the steps.
1. Examine the power supply and motor: You should first make sure the power line is intact and the voltage and frequency are within acceptable ranges. In the meantime, make sure the motor's wiring is accurate, its insulation resistance is appropriate, and its bearings are properly greased.
2. Check the pump body and its accessories: Make sure the body is clean and clear of debris, and look for any cracks, deformation, or other flaws. Check the import and export valves simultaneously to make sure they are leak-free, flexible, and unbroken. Additionally, make sure there is no jamming and that the pump shaft is rotating flexibly.
3. Test the lubricant: If the self-priming water pump has a lubrication system, make sure the system is clear of obstructions and has enough clean lubricant. Please check the oil temperature and level to make sure they are both within normal limits at the same time.
4. Inspect the sealing device: One of the most important components to guarantee the proper functioning of a self-priming pump is the sealing device. Make sure the sealing surface is flat and unharmed before beginning, as well as that the sealing device is in one piece. Whats’ more, you had better process any loosening phenomena and make sure the seals are installed correctly at the same time.
5. Inspect the cooling system: For self-priming pumps that require cooling, make sure the cooling water pipeline is smooth, the cooling water flow is regular, and the cooling system is intact. In order to prevent damage to the pump body, simultaneously verify that the cooling water temperature is not excessively high.
6. Examine the installation environment: Determine whether the self-priming pump installation environment satisfies the specifications, including whether the foundation is level and sturdy and whether there are no nearby obstructions. Meanwhile, you should check the temperature and humidity 7. Perform a no-load test run: This should be done prior to beginning. First, shut off the inlet and exit valves, turn on the motor, and verify to see whether it is operating normally and if any strange noises are coming from it. Next, open the inlet valve and check for leaks in the pump body.
8. Assess the self-priming performance: This should be done in the no-load test that is conducted following the regular test. First, turn on the motor, open the input valve, and close the export valve. Next, try to see if the pump body can routinely suction and discharge water. The following action can be taken if the self-priming performance is satisfactory. levels as well as the pump room's ventilation.
9. Testing the pressure and flow in step three. If the self-priming performance check is normal, open the outlet valve gradually and make sure the pump's pressure and flow satisfy the specifications. Monitor the pump body for unusual vibration, noise, and other occurrences simultaneously. It can be tested for a long period if everything is normal.
10. Long-term test: During this type of test, it's important to make sure that the temperature, flow, pressure, and other parameters of the pump remain constant. In the meantime, make sure the bearing lubrication is normal and the motor temperature is not too high. It can be concluded that the preparation and testing tasks necessary before turning on the self-priming centrifugal pump have been finished if the lengthy test runs normally.